Part Number DOT-BRMC-0604, DOT-BRMC Series 3/8 in. Tube x 1/4 in. NPTF Male Connector Fitting
$9.13
| SKU | DOT-BRMC-0604 |
|---|---|
| Category | Fittings |
| Tube OD | 3/8 in |
| D1 NPTF | 1/4 in |
| D2 | 0.630 in |
| L1 | 0.512 in |
| L2 | 1.299 in |
| Hex | 11/16 in |
| Weight Each | 0.067 lb |
| Brand | Kuri Tec® |
| Type | Push-To-Connect Straight Connector Fittings |
| Style | Male |
| Series | DOT-BRMC |
| Max. Pressure | 290 psi |
| Vacuum Rating | 29 inHg |
| Tubing Insertion Depth L | 0.720 in |
| Norm Reference | ANSI/ASME B1.20.3 |
| Tightening Torque | 3.32 ft·lb |
| Thread | Tube |
| Thread 2 | NPTF PTFE Coated |
General Applications
Pneumatic circuits for truck and trailers: air suspension, braking systems, transmissions, locking doors and windows, seat adjustment, instrumentation, air conditioning systems, horn, wiper motors, valves, cylinders and accessories.Suitable for all air assisted applications except those designed for use between frame and axle or between towed and towing vehicles.
Construction
Brass housing with polyethylene holding ring and nitrile (NBR) seals.
Body and Release
Brass UNI EN 12164 CW614N - UNI EN 12165 CW617N
Seals
NBR (Low Temperature)
Holding Ring
Resin (PEI)
Gripping Collet
Stainless Steel AISI 301
Protection Ring
Resin (PEI)
Tube
Tube Support (in)
Recommended Tubing
Designed to work with Endure™ Air Brake tubing or other tubing that complies with DOT FMVSS 106 and meets the performance requirements of SAE J844.
Temperature [Min]
-50 ºC
Temperature [Max]
100 ºC
Assembly Instructions
Cut the tube square (with a hose cutter) making sure that there are no burrs and that the tube is round.Insert the tube into the fitting until it bottoms.Tube releaseWhile pressing on the release ring, pull the tube from the fitting.Once the tubing is connected to the fitting, make sure that the tubing is not pulled or stretched and that the minimum bend radius stated in the tubing section of this catalog is not exceeded.To prevent accidental tube release, be certain that nothing comes in contact with the release ring. Any load on the release ring may cause an unwanted disconnection.